B.D.C. Inc. - Item # Honeywell STT250, Honeywell STT250 Temperature Transmitter
BDC - Burner Design and Control - Specialists in Process Heating and Control BDC - Burner Design and Control - Specialists in Process Heating and Control BDC - Burner Design and Control - Specialists in Process Heating and Control
Home   Services   Systems Integration   Manufacturers   Hot Deals   About Us   RFQ   Contact Us  
     
Products

Actuators

Analytical Instruments

Burners

Burner Controls

Data Acquisition

Flow Meters

Fuel Standby Systems

Gas Regulators

Heat Exchangers

Pressure Transmitters & Switches

Process Control

Recorders

Temperature Transmitters

Valves

Wireless Transmitters

  Temperature Sensors
  Gas Regulators

Products

 Search Catalog
      GO   
 All Categories    Honeywell STT250 Temperature Transmitter
View CartView RFQ'sExpress Ordering
 Shopping Cart  0 items 
 Request for Quote  0 items 
All Categories > Temperature Transmitters > Honeywell STT250 Temperature Transmitter > Item # Honeywell STT250  
Request Information

Honeywell STT250 Temperature Transmitter

QUOTE



    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

STT250 Temperature Transmitter

larger image
Honeywell STT250 Temperature Transmitter
  • Memory contains the characteristics of most commonly used temperature sensors.
  • Calibration of the LRV/URV end points will typically give accuracy improvements of 2 times.
  • Sensor errors can be calibrated out by calibration to the specific sensor either by having it at the LRV/URV temperatures or by simulation of the known values.



 Specifications  Approvals  

Load Resistance

0 to 1110 O

Max. Shock

40 G

Cold Junction Accuracy

±0.5 ºC

Output Current

Current over range 3.8 to 20.8 mA. Failsafe limits < 3.8 and 21.8 mA

Vibrations

Maximum of 4g over 15 to 200Hz (restricted to 3g with indication meter).

Output D/A Accuracy

±0.025% of span

Material of Construction

Terminal Block - Noryl
Connection Screws - M3 Nickel plated brass
Module Housing - Cycoloy (PC/ABS) with metallised interior surface

Weight

0.2 lb
0.075 kg

Materials

304SS
316L SS
316SS
Carbon Steel
Hastelloy C-276
Monel 400

Thermowell Types

Threaded or flanged, with or without lagging and solid drilled, forged or fabricated construction

Flange Types

Raised Face, Flat Face and Ring Type joint flanges available in 1 to 3 inch sizes or 15 to 200mm

Flange Ratings

ANSI 150 to 2500, BS 4504 NP6 to NP100, BS 10 Tables D to K and API 6A 5000 to 15000lb

Physical Mounting, Construction and Integral Meters

The STT250 Temperature Transmitter is designed to be mounted in a DIN Form A housing for direct installation with the temperature sensor or can be provided in a remote pipe or wall mount housing. Details on the various housings and integral meters available are given in specification sheet EN0I- 6032. The STT250 Temperature Transmitter module can also be DIN rail mounted to a top hat or “G” rail via a clip.

Probe and Thermowell Availability

STT250 can be supplied complete with any of the previously listed thermocouple or RTD sensors and with any of a wide range of thermowells. The sensors are of Mineral Insulated (MI) construction with lengths of up to 2 meters available. For the direct head mount installation the sensor is supplied with a mounting plate for STT250 module attachment and fixing screws to provide the spring loaded attachment to the housing. For EEx d IIC T6 applications a flame trap is included between the sensor and sensor entry of the housing. See details on the standard sensors available in EN0I-6033 for Europe, or 34-44-29-01 for North America.

Additional Parameters

Output: 4-20mA or Honeywell digital DE protocol. HART and DE available with 4- 20mA output.
Adjustment range: No limits to adjustments within the Maximum Range except minimum span limit of 1 engineering unit e.g. 1°C
Damping time constant: Adjustable from 0 to 102 seconds digital damping.
Output response time: 1 second to reach 63% of final value with 0 secs damping.
Output update time 0.5 secs approximately.
Input/ output galvanic isolation Withstands 500Vac dielectric strength test for 1 minute.
Sensor open circuit Open circuit/ burnout detection is user selectable. Upscale or downscale with critical status message. Latching or nonlatching sensor burnout action.
Common mode rejection 120dB (1 million to 1) from 50Hz to 50 kHz.
Series mode rejection 40dB (100 to 1) for 50 or 60Hz ±0.5Hz. with internal software filter set to local power line frequency).
EMC compliance
In compliance with 89/336/EEC, ElectroMagnetic Compatibility (EMC) Directive.
RFI rejection: ±0.1% of span at 30V/m over 20 to 1,000MHz in metallic housing and with shielded cables.

 DOWNLOADS 

 width= Specification Sheet
(PDF, 455KB)


Request Information
     